Three Phase Inverter - 120 Degree Conduction Mode

Rakesh Kumar, Ph.D. | 09/10 |
Rakesh Kumar, Ph.D. 20587 09/10 2023-10-09 10:51:32

Overview: This technical piece shows how the three-phase inverter works in the 120-degree conduction mode. To make things easier to understand, the six thyristors' functions and the patterns that go with them are shown.

 

Three-phase transformers are mostly used for tasks that need medium to high power. These days, three-phase inverters are used to precisely control things like motor drives, solar power plants, and industrial drives. One can also control the power and frequency with these inverters, among other things.

 

As seen in Figure 1, the three-phase inverters use at least six thyristor switches. From a direct current (DC) input, this type of power electronics converter creates a three-phase alternating current (AC) output.

Figure 1. Circuit diagram of a three phase inverter. Image used courtesy of Rakesh Kumar, Ph.D.

It has three legs, and two thyristors are on each leg. The thyristors in the lower leg are numbered even, while the ones in the upper leg are numbered odd. The load that is linked in a star connected is tapped in the middle of each leg, where the two thyristors meet.

 

 

Three Phase Inverter Operatation in 120 Degree Conduction Mode

Different thyristors' transmission periods are shown in Figure 2 for each 60-degree part of the full 360-degree cycle. And so, there are six ways to use it. Each thyristor can be seen to conduct for 2*60 degrees, which is 120 degrees all the time.

 

Each leg's pair of thyristors is 180 degrees out of phase with the other pair. In other words, there is only one thyristor on in each leg at any given time. Another thing that can be seen is that each thyristor is 120 degrees out of phase with the thyristor next to it on the next leg.

Figure 2. Operating periods of the thyristors for every 60 degree in 120 degree conduction mode of three phase inverter. Image used courtesy of Rakesh Kumar, Ph.D.

Operating Mode 1 - 0 to 60 Degree [M1]

Mode 1 corresponds to a 0 to 60 degree period. During this period, the thyristors T1, and T6 are turned on. This can be seen in Figure 3.

 

On the load side, the current enters phase a and leaves via phase b. The equivalent circuit diagram of the same is placed on the right side of Figure 3.

 

On applying the voltage division rule, the phase-to-neutral voltages are as follows:

 

Van = Vin/2           (1)

Vbn = -Vin/2         (2)

Vcn = 0                  (3)

 

The phase-to-phase voltages are as follows:

 

Vab = Van - Vbn =  Vin          (4)

Vbc = Vbn - Vcn = -Vin/2      (5)

Vca = Vcn - Van = -Vin/2      (6)

Figure 3. Mode 1 operation of a three phase inverter in 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D.

Operating Mode 2 - 60 to 120 Degree [M2]

Mode 2 corresponds to a 60 to 120 degree period. During this period, the thyristors T1, and T2 are turned on. This can be seen in Figure 4.

 

On the load side, the current enters phase a and leaves via phase c. The equivalent circuit diagram of the same is placed on the right side of Figure 4.

 

On applying the voltage division rule, the phase-to-neutral voltages are as follows:

 

Van = Vin/2            (7)

Vbn = 0                   (8)

Vcn = -Vin/2           (9)

 

The phase-to-phase voltages are as follows:

 

Vab = Van - Vbn =  Vin/2       (10)

Vbc = Vbn - Vcn =  Vin/2       (11)

Vca = Vcn - Van = -Vin           (12)

Figure 4. Mode 2 operation of a three phase inverter in 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D.

Operating Mode 3 - 120 to 180 Degree [M3]

Mode 3 corresponds to a 120 to 180 degree period. During this period, the thyristors T2, and T3 are turned on. This can be seen in Figure 5.

 

On the load side, the current enters phase b and leaves via phase c. The equivalent circuit diagram of the same is placed on the right side of Figure 5.

 

On applying the voltage division rule, the phase-to-neutral voltages are as follows:

 

Van = 0                  (13)

Vbn = Vin/2           (14)

Vcn = -Vin/2          (15)

 

The phase-to-phase voltages are as follows:

 

Vab = Van - Vbn = -Vin/2     (16)

Vbc = Vbn - Vcn =  Vin         (17)

Vca = Vcn - Van = -Vin/2     (18)

Figure 5. Mode 3 operation of a three phase inverter in 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D.

Operating Mode 4 - 180 to 240 Degree [M4]

Mode 4 corresponds to a 180 to 240 degree period. During this period, the thyristors T3, and T4 are turned on. This can be seen in Figure 6.

 

On the load side, the current enters phase b and leaves via phase c. The equivalent circuit diagram of the same is placed on the right side of Figure 6.

 

On applying the voltage division rule, the phase-to-neutral voltages are as follows:

 

Van = -Vin/2         (19)

Vbn = Vin/2          (20)

Vcn = 0                  (21)

 

The phase-to-phase voltages are as follows:

 

Vab = Van - Vbn = -Vin     (22)

Vbc = Vbn - Vcn = Vin/2   (23)

Vca = Vcn - Van = Vin/2   (24)

Figure 6. Mode 4 operation of a three phase inverter in 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D

Operating Mode 5 - 240 to 300 Degree [M5]

Mode 5 corresponds to a 240 to 300 degree period. During this period, the thyristors T4, and T5 are turned on. This can be seen in Figure 7.

 

On the load side, the current enters phase c leaves via phase a. The equivalent circuit diagram of the same is placed on the right side of Figure 7.

 

On applying the voltage division rule, the phase-to-neutral voltages are as follows:

 

Van = -Vin/2       (25)

Vbn = 0                (26)

Vcn = Vin/2         (27)

 

The phase-to-phase voltages are as follows:

 

Vab = Van - Vbn = -Vin/2  (28)

Vbc = Vbn - Vcn = -Vin/2  (29)

Vca = Vcn - Van = Vin        (30)

Figure 7. Mode 5 operation of a three phase inverter in 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D.

Operating Mode 6 - 300 to 360 Degree  [M6]

Mode 6 corresponds to a 300 to 360 degree period. During this period, the thyristors T5, and T6 are turned on. This can be seen in Figure 8.

 

On the load side, the current enters phase c and leaves via phase b. The equivalent circuit diagram of the same is placed on the right side of Figure 8.

 

On applying the voltage division rule, the phase-to-neutral voltages are as follows:

 

Van = 0                  (31)

Vbn = -Vin/2         (32)

Vcn =  Vin/2          (33)

 

The phase-to-phase voltages are as follows:

 

Vab = Van - Vbn = Vin/2      (34)

Vbc = Vbn - Vcn = -Vin         (35)

Vca = Vcn - Van =  Vin/2      (36)

Figure 8. Mode 6 operation of a three phase inverter in 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D.

Output Phase-to-Neutral Voltage Waveforms of the Three Phase Inverter

Figure 9 shows the load phase-to-neutral voltage waveforms for a single cycle (360 degree). It can be observed that an individual phase-to-phase voltage waveform is continuous for 120 degree, followed by a zero voltage.

 

The other observation is that each of the phase-to-neutral voltage waveforms is phase shifted by 120 degree. All three waveforms put together assume a three phase output.

Figure 9. Phase-to-neutral waveforms of three phase inverter under 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D.

Output Phase-to-Phase Voltage Waveforms of the Three Phase Inverter

Figure 10 shows the load phase-to-phase voltage waveforms for a single cycle (360 degree). It can be observed that an individual phase-to-neutral voltage waveform varies in steps during each 60 degree phase.

 

The other observation is that each of the phase-to-phase voltage waveforms is also phase shifted by 120 degree, just like the phase-to-neutral voltage waveform.

Figure 10. Phase-to-phase waveforms of a three phase inverter in 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D.

If you want to see the whole piece in one picture, look at Figure 11. It shows all six modes of operation as an animated GIF.

Figure 11. A GIF illustrating all six modes of operation of the three phase inverter in 120 degree conduction mode. Image used courtesy of Rakesh Kumar, Ph.D.

RakeshKumarPh.D.

Email : rakesh.a@ieee.org

Rakesh Kumar holds a Ph.D. in Electrical Engineering with a specialization in Power Electronics from Vellore Institute of Technology, India. He is a Senior Member of IEEE, Class of 2021, and a member of the IEEE Power Electronics Society (PELS). Rakesh is a committee member of the IEEE PELS Education Steering Committee headed by Prof. Katherine Kim. He is passionate about writing high-quality technical articles of high interest to readers of the JAK Electronics Community.

Popular Post

Blog

Introduction to Nexperia Automotive-Grade ICs

Electronics in the automotive industry require accuracy, durability and complete reliability. All systems, including the engine control and modern driver assist, are based on parts that have to endure both high temperature and electrical interference, as well as extended durability of operation.

Blog

ASIC vs FPGA Comparison: Performance, Cost, and Design Differences Explained

This article compares Application-Specific Integrated Circuits (ASICs) and Field-Programmable Gate Arrays (FPGAs), two technologies used for creating custom digital circuits.

Solution

The Rise of Automotive-Grade SiC/GaN Power Devices in Electric Vehicles

The automotive fast recovery Silicon Carbide (SiC) and Gallium Nitride (GaN) power devices emerge as game-changing technologies.

Blog

How to Safely Discharge an AC Capacitor

AC capacitor discharge refers to the process in which a capacitor releases its stored electrical energy in an alternating current (AC) circuit.

Blog

Signs of a Bad Camshaft Position Sensor and How to Test it?

A car has a variety of electrical components, one of which is called a camshaft position sensor (CMP). This section will discuss this component, the signs that indicate a problematic camshaft position sensor, and the procedures for doing so.

Blog

Symptoms of a Bad Speed Sensor and How to Test It?

Speed sensors are utilized to measure the speed at which devices are spinning. Many vehicles, including automobiles, aerospace vehicles, off-highway and construction equipment, railway vehicles, and military vehicles, require speed sensors.

Blog

Current Divider: definition, applications & formula

A current divider is an electrical circuit configuration used to split or divide an input current into multiple branches or paths.

Solution

74LS04 Hex Inverter Datasheet(PDF) and Pinout

This article will explain some detailed information about 74LS04 Hex Inverter, including its datasheet, pinout, features and specifications.

Recommend Products

AT17LV256-10JI

Microchip Technology

24LC00T-I/ST

Microchip Technology

MT53E128M32D2DS-053 WT:A

Micron Technology Inc.

AT24C01A-10TI-1.8

Microchip Technology

AT27C4096-55PC

Microchip Technology

24LC00T-I/ST

Microchip Technology

IC EEPROM 128 I2C 400KHZ 8TSSOP

AT27C4096-55PC

Microchip Technology

IC EPROM 4M PARALLEL 40DIP

MT8HTF12864HZ-667H1

Micron Technology Inc.

DRAM Module DDR2 SDRAM 1Gbyte 200SODIMM