| Compare | Image | Part # | Manufacturer | Description | Availability | Pricing | Quantity | RoHS | Factory Lead Time | Mount | Mounting Type | Package / Case | Published | Series | Tolerance | Part Status | Moisture Sensitivity Level (MSL) | Termination | Type | Termination Style | Circuit | Throw Configuration | Switching Cycles | Current Rating - AC | Switching Temperature | Current Rating - DC | Reset Temperature | RoHS Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Datasheet
| Mfr. Part #A1009005MOST Part #137-836-A1009005 | Cantherm |
THERMOSTAT 90DEG C SPST-NC MODUL
| Min.:1 Mult.:1 | 5 Weeks | Chassis Mount | Chassis Mount | Module | 2009 | A10V | ±9°F ±5°C | Active | 1 (Unlimited) | - | Mechanical | User Defined | SPST-NC | SPST | 6K | 2.5A 250V | 194°F 90°C | - | - | ROHS3 Compliant | ||||
| A1009005 | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #F20B06505ACFA06EMOST Part #137-836-F20B06505ACFA06E | Cantherm |
THERMOSTAT 65DEG C SPST-NO WIRE
| Min.:1 Mult.:1 | 5 Weeks | Through Hole | Through Hole | Potted - Wire Leads | - | F20 | ±9°F ±5°C | Active | Not Applicable | - | - | Wire Leads - 6 (152.4mm) | SPST-NO | - | 7K | 1.6A 250V | 149°F 65°C | - | 95°F 35°C | ROHS3 Compliant | ||||
| F20B06505ACFA06E | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #F20A15505DCFB06EMOST Part #137-836-F20A15505DCFB06E | Cantherm |
THERMOSTAT 155DEG C SPST-NC WIRE
| Min.:1 Mult.:1 | 5 Weeks | Through Hole | Through Hole | Housed Sensor | 2009 | F20 | ±9°F ±5°C | Active | Not Applicable | Wire Leads | Mechanical | Wire Leads - 4 (101.6mm) | SPST-NC | SPST | 7K | 1.6A 250V | 311°F 155°C | - | 257°F 125°C | ROHS3 Compliant | ||||
| F20A15505DCFB06E | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #F20A08505ACPA06EMOST Part #137-836-F20A08505ACPA06E | Cantherm |
THERMOSTAT 85DEG C SPST-NC 2SIP
| Min.:1 Mult.:1 | 5 Weeks | Through Hole | Through Hole | 2-SIP, Potted | - | F20 | ±9°F ±5°C | Active | Not Applicable | - | - | Wire Leads - 4 (101.6mm) | SPST-NC | - | 7K | 1.6A 250V | 185°F 85°C | - | 131°F 55°C | ROHS3 Compliant | ||||
| F20A08505ACPA06E | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #M3000XBARBMOST Part #137-836-M3000XBARB | Cantherm |
THERMOSTAT 0 DEG C SPST-NC RECT
| Min.:1 Mult.:1 | 5 Weeks | Chassis Mount | Chassis Mount | Rectangular Case | 2010 | M3 | ±7.2°F ±4°C | Active | - | - | - | - | SPST-NC | - | 7K | 3A 125V 5A 125V | 32°F 0°C | 3A 24V 5A 12V | 23.9°F -4.5°C | ROHS3 Compliant | ||||
| M3000XBARB | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #F20A07005ACLA06EMOST Part #137-836-F20A07005ACLA06E | Cantherm |
THERMOSTAT 70DEG C SPST-NC 2SIP
| Min.:1 Mult.:1 | 5 Weeks | - | Through Hole | 2-SIP | 2009 | F20 | ±9°F ±5°C | Active | Not Applicable | - | - | Wire Leads - 4 (101.6mm) | SPST-NC | - | 7K | 1.6A 250V | 158°F 70°C | - | 104°F 40°C | ROHS3 Compliant | ||||
| F20A07005ACLA06E | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #A1007005MOST Part #137-836-A1007005 | Cantherm |
THERMOSTAT 70DEG C SPST-NC MODUL
| Min.:1 Mult.:1 | 5 Weeks | Chassis Mount | Chassis Mount | Module | 2009 | A10V | ±9°F ±5°C | Active | 1 (Unlimited) | - | Mechanical | User Defined | SPST-NC | SPST | 6K | 2.5A 250V | 158°F 70°C | - | - | ROHS3 Compliant | ||||
| A1007005 | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #H702S 350MOST Part #137-836-H702S 350 | Cantherm |
THERMOSTAT SENSOR 350C 5-24V 3A
| Min.:1 Mult.:1 | 7 Weeks | - | - | - | 2016 | - | - | Active | 1 (Unlimited) | - | - | - | - | - | - | - | - | - | - | ROHS3 Compliant | ||||
| H702S 350 | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #B12A05505AEDA0GEMOST Part #137-836-B12A05505AEDA0GE | Cantherm |
THERMAL PROTECTOR 55DEG C NC 6A
| Min.:1 Mult.:1 | - | Through Hole | Through Hole | Radial | 2006 | B12 | ±9°F ±5°C | Obsolete | Not Applicable | Wire Leads | - | Wire Leads - 4 (101.6mm) | SPST-NC | SPST | 1K | 6A 250V | 131°F 55°C | - | 77°F 25°C | RoHS Compliant | ||||
| B12A05505AEDA0GE | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #B12A05005AEDA0GEMOST Part #137-836-B12A05005AEDA0GE | Cantherm |
THERMAL PROTECTOR 50DEG C NC 6A
| Min.:1 Mult.:1 | - | Through Hole | Through Hole | Radial | - | B12 | ±9°F ±5°C | Obsolete | Not Applicable | Wire Leads | - | Wire Leads - 4 (101.6mm) | SPST-NC | SPST | 1K | 6A 250V | 122°F 50°C | - | 68°F 20°C | RoHS Compliant | ||||
| B12A05005AEDA0GE | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #B12B05505AEDA0GEMOST Part #137-836-B12B05505AEDA0GE | Cantherm |
THERMAL PROTECTOR 55DEG C N/O 6A
| Min.:1 Mult.:1 | - | Through Hole | Through Hole | Radial | 2006 | B12 | ±9°F ±5°C | Obsolete | Not Applicable | Wire Leads | - | Wire Leads - 4 (101.6mm) | SPST-NO | SPST | 5K | 1.6A 250V | 131°F 55°C | - | 77°F 25°C | RoHS Compliant | ||||
| B12B05505AEDA0GE | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #B12B05005AEDA0GEMOST Part #137-836-B12B05005AEDA0GE | Cantherm |
THERMAL PROTECTOR 50DEG C N/O 6A
| Min.:1 Mult.:1 | - | Through Hole | Through Hole | Radial | 2006 | B12 | ±9°F ±5°C | Obsolete | Not Applicable | Wire Leads | - | Wire Leads - 4 (101.6mm) | SPST-NO | SPST | 5K | 1.6A 250V | 122°F 50°C | - | 68°F 20°C | RoHS Compliant | ||||
| B12B05005AEDA0GE | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #A1014005MOST Part #137-836-A1014005 | Cantherm |
THERMOSTAT A10 140 5C AUTO RESET
| Min.:1 Mult.:1 | 5 Weeks | Chassis Mount | Chassis Mount | Module | 2009 | A10V | ±9°F ±5°C | Active | 1 (Unlimited) | - | Mechanical | User Defined | SPST-NC | SPST | 6K | 2.5A 250V | 284°F 140°C | - | - | ROHS3 Compliant | ||||
| A1014005 | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #A1006505MOST Part #137-836-A1006505 | Cantherm |
THERMOSTAT 65DEG C SPST-NC MODUL
| Min.:1 Mult.:1 | 5 Weeks | Chassis Mount | Chassis Mount | Module | 2009 | A10V | ±9°F ±5°C | Active | 1 (Unlimited) | - | Mechanical | User Defined | SPST-NC | SPST | 6K | 2.5A 250V | 149°F 65°C | - | - | ROHS3 Compliant | ||||
| A1006505 | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #MQT8H 50XBMOST Part #137-836-MQT8H 50XB | Cantherm |
THERMOSTAT 50DEG C SPST-NC RECT
| Min.:1 Mult.:1 | 7 Weeks | - | Free Hanging | Rectangular Case | - | MQT | ±5.4°F ±3°C | Active | Not Applicable | - | - | Wire Leads - 5.91 (150mm) | SPST-NC | - | 100K | 0.9A 250V 1.5A 125V | 122°F 50°C | 0.3A 48V 1.5A 12V | 114°F 45.5°C | ROHS3 Compliant | ||||
| MQT8H 50XB | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #MQT8H 90XCMOST Part #137-836-MQT8H 90XC | Cantherm |
THERMOSTAT 90DEG C SPST-NC RECT
| Min.:1 Mult.:1 | 7 Weeks | - | Free Hanging | Rectangular Case | - | MQT | ±9°F ±5°C | Active | Not Applicable | - | - | Wire Leads - 5.91 (150mm) | SPST-NC | - | 100K | 1.3A 250V 2A 125V | 194°F 90°C | 0.3A 48V 2A 12V | 182°F 83.5°C | ROHS3 Compliant | ||||
| MQT8H 90XC | ||||||||||||||||||||||||||||
Datasheet
| Mfr. Part #MQT8K 060XB2, 950LMOST Part #137-836-MQT8K 060XB2, 950L | Cantherm |
THERMOSTAT CTRL 60 DEG C NC 2A
| Min.:1 Mult.:1 | 7 Weeks | - | - | - | - | - | - | Active | Not Applicable | - | - | - | - | - | - | - | - | - | - | ROHS3 Compliant | ||||
| MQT8K 060XB2, 950L |
Temperature Sensors - Thermostats - Mechanical definition: Temperature Sensors - Thermostats - Mechanical Product Listing: A1009005,F20B06505ACFA06E,F20A15505DCFB06E,F20A08505ACPA06E,M3000XBARB.Sensors, Transducers type:Pressure Sensors, Transducers(84536),Current Sensors(57379),Encoders(27450),Proximity Sensors(21296),Sensor Cable - Assemblies(20019) .Temperature Sensors - Thermostats - Mechanical has 277 pieces of spot stock price information, you can click the "RFQ" button to confirm the inventory and price with the MOST.